Sun Windows, Inc.

Product Performance Data

Clad Thermal Performance (Cardinal 270, 366, E180 and i89 )

NFRC 100/200/500

SunClad Direct Set Replacement



Glazing

Glass







Product

Grid Type

Glazing Description

U-Value

R-Value

SHGC

VT

CR











USA Repl. Direct Set Fixed

N

DG

D

3/4" I.G.; 270 #2/Clr

0.29

3.45

0.33

0.63

57

USA Repl. Direct Set Fixed

N

DG

D

3/4" I.G.; 270 #2/i89 #4

0.24

4.17

0.33

0.62

46

USA Repl. Direct Set Fixed

N

DG

D

3/4" I.G.; Bronze Tint/270 #3

0.29

3.45

0.33

0.47

57

USA Repl. Direct Set Fixed

N

DG

D

3/4" I.G.; 366 #2/clr

0.28

3.57

0.25

0.58

58

USA Repl. Direct Set Fixed

N

DG

D

3/4" I.G.; 366 #2/i89 #4

0.24

4.17

0.24

0.57

46

USA Repl. Direct Set Fixed

N

DG

D

3/4" I.G.; Bronze tint/366 #3

0.28

3.57

0.28

0.44

58

USA Repl. Direct Set Fixed

N

DG

D

3/4" I.G.; Clr / E180 #3

0.30

3.33

0.62

0.71

57

USA Repl. Direct Set Fixed

N

TG

D

.98" I.G.; 270 #2/Clr/Clr

0.25

4.00

0.31

0.58

63

USA Repl. Direct Set Fixed

N

TG

D

.98" I.G.; 270 #2/Clr/i89 #6

0.22

4.55

0.30

0.56

50

USA Repl. Direct Set Fixed

N

TG

D

.98" I.G.; 366 #2/Clr/Clr

0.25

4.00

0.23

0.53

63

USA Repl. Direct Set Fixed

N

TG

D

.98" I.G.; 366 #2/Clr/i89 #6

0.22

4.55

0.22

0.52

50

USA Repl. Direct Set Fixed

N

TG

D

.98" I.G.; 270 #2/Clr/E180 #5

0.22

4.55

0.30

0.55

67

USA Repl. Direct Set Fixed

N

TG

D

.98" I.G.; 366 #2/Clr/E180 #5

0.22

4.55

0.22

0.51

67

USA Repl. Direct Set Fixed

GBG

DG

D

3/4" I.G.; 270 #2/Clr

0.30

3.33

0.30

0.57

57

USA Repl. Direct Set Fixed

GBG

DG

D

3/4" I.G.; 270 #2/i89 #4

0.26

3.85

0.30

0.55

46

USA Repl. Direct Set Fixed

GBG

DG

D

3/4" I.G.; Bronze Tint/270 #3

0.30

3.33

0.30

0.42

57

USA Repl. Direct Set Fixed

GBG

DG

D

3/4" I.G.; 366 #2/clr

0.30

3.33

0.22

0.52

58

USA Repl. Direct Set Fixed

GBG

DG

D

3/4" I.G.; 366 #2/i89 #4

0.25

4.00

0.22

0.51

46

USA Repl. Direct Set Fixed

GBG

DG

D

3/4" I.G.; Bronze tint/366 #3

0.30

3.33

0.25

0.39

58

USA Repl. Direct Set Fixed

GBG

DG

D

3/4" I.G.; Clr / E180 #3

0.31

3.23

0.56

0.64

57

USA Repl. Direct Set Fixed

GBG

TG

D

.98" I.G.; 270 #2/Clr/Clr

0.27

3.70

0.28

0.52

63

USA Repl. Direct Set Fixed

GBG

TG

D

.98" I.G.; 270 #2/Clr/i89 #6

0.23

4.35

0.27

0.51

50

USA Repl. Direct Set Fixed

GBG

TG

D

.98" I.G.; 366 #2/Clr/Clr

0.26

3.85

0.21

0.48

63

USA Repl. Direct Set Fixed

GBG

TG

D

.98" I.G.; 366 #2/Clr/i89 #6

0.23

4.35

0.21

0.47

50

USA Repl. Direct Set Fixed

GBG

TG

D

.98" I.G.; 270 #2/Clr/E180 #5

0.23

4.35

0.27

0.50

67

USA Repl. Direct Set Fixed

GBG

TG

D

.98" I.G.; 366 #2/Clr/E180 #5

0.23

4.35

0.21

0.46

67

USA Repl. Direct Set Fixed

5/8" SDL

DG

D

3/4" I.G.; 270 #2/Clr

0.30

3.33

0.30

0.57

57

USA Repl. Direct Set Fixed

5/8" SDL

DG

D

3/4" I.G.; 270 #2/i89 #4

0.26

3.85

0.30

0.55

46

USA Repl. Direct Set Fixed

5/8" SDL

DG

D

3/4" I.G.; Bronze Tint/270 #3

0.30

3.33

0.30

0.42

57

USA Repl. Direct Set Fixed

5/8" SDL

DG

D

3/4" I.G.; 366 #2/clr

0.30

3.33

0.22

0.52

58

USA Repl. Direct Set Fixed

5/8" SDL

DG

D

3/4" I.G.; 366 #2/i89 #4

0.25

4.00

0.22

0.51

46

USA Repl. Direct Set Fixed

5/8" SDL

DG

D

3/4" I.G.; Bronze tint/366 #3

0.30

3.33

0.25

0.39

58

USA Repl. Direct Set Fixed

5/8" SDL

DG

D

3/4" I.G.; Clr / E180 #3

0.31

3.23

0.56

0.64

57

USA Repl. Direct Set Fixed

5/8" SDL

TG

D

.98" I.G.; 270 #2/Clr/Clr

0.27

3.70

0.28

0.52

63

USA Repl. Direct Set Fixed

5/8" SDL

TG

D

.98" I.G.; 270 #2/Clr/i89 #6

0.23

4.35

0.27

0.51

50

USA Repl. Direct Set Fixed

5/8" SDL

TG

D

.98" I.G.; 366 #2/Clr/Clr

0.26

3.85

0.21

0.48

63

USA Repl. Direct Set Fixed

5/8" SDL

TG

D

.98" I.G.; 366 #2/Clr/i89 #6

0.23

4.35

0.21

0.47

50

USA Repl. Direct Set Fixed

5/8" SDL

TG

D

.98" I.G.; 270 #2/Clr/E180 #5

0.23

4.35

0.27

0.50

67

USA Repl. Direct Set Fixed

5/8" SDL

TG

D

.98" I.G.; 366 #2/Clr/E180 #5

0.23

4.35

0.21

0.46

67

USA Repl. Direct Set Fixed

>=1" SDL

DG

D

3/4" I.G.; 270 #2/Clr

0.30

3.33

0.27

0.51

57

USA Repl. Direct Set Fixed

>=1" SDL

DG

D

3/4" I.G.; 270 #2/i89 #4

0.26

3.85

0.27

0.49

46

USA Repl. Direct Set Fixed

>=1" SDL

DG

D

3/4" I.G.; Bronze Tint/270 #3

0.30

3.33

0.27

0.38

57

USA Repl. Direct Set Fixed

>=1" SDL

DG

D

3/4" I.G.; 366 #2/clr

0.30

3.33

0.20

0.47

58

USA Repl. Direct Set Fixed

>=1" SDL

DG

D

3/4" I.G.; 366 #2/i89 #4

0.25

4.00

0.20

0.46

46

USA Repl. Direct Set Fixed

>=1" SDL

DG

D

3/4" I.G.; Bronze tint/366 #3

0.30

3.33

0.23

0.35

58

USA Repl. Direct Set Fixed

>=1" SDL

DG

D

3/4" I.G.; Clr / E180 #3

0.31

3.23

0.50

0.57

57

USA Repl. Direct Set Fixed

>=1" SDL

TG

D

.98" I.G.; 270 #2/Clr/Clr

0.27

3.70

0.25

0.46

63

USA Repl. Direct Set Fixed

>=1" SDL

TG

D

.98" I.G.; 270 #2/Clr/i89 #6

0.23

4.35

0.25

0.45

50

USA Repl. Direct Set Fixed

>=1" SDL

TG

D

.98" I.G.; 366 #2/Clr/Clr

0.26

3.85

0.19

0.43

63

USA Repl. Direct Set Fixed

>=1" SDL

TG

D

.98" I.G.; 366 #2/Clr/i89 #6

0.23

4.35

0.19

0.42

50

USA Repl. Direct Set Fixed

>=1" SDL

TG

D

.98" I.G.; 270 #2/Clr/E180 #5

0.23

4.35

0.25

0.45

67

USA Repl. Direct Set Fixed

>=1" SDL

TG

D

.98" I.G.; 366 #2/Clr/E180 #5

0.23

4.35

0.19

0.41

67











* all simulations are 90% Argon filled, unless noted otherwise










*"DG" = Dual Glazed; "TG" = Triple Glazed










Glass codes(nominal): "D" - double strength(.117"/3.0mm), "T" - triple strength(.187"/5.0mm)




















Last Update: 2/15/2017 12:00:00 AM